TY - JOUR A2 - Cao, Xiangyu AU - Liu, Ji-Xuan AU - Sun, Zhi-Jun AU - Wang, Jin-Da PY - 2021 DA - 2021/04/23 TI - Renal Arteriography via Radial Artery Access with a 125 cm Long Angiographic Catheter SP - 5564462 VL - 2021 AB - A 125 cm long catheter makes it possible to perform renal arteriography via radial artery, but its feasibility and safety remain unclear. Our study recruited 1,323 patients grouped by two different vascular accesses to renal arteriography, i.e., femoral artery access and radial artery access. The success rate of angiography was 100% in both groups. Differential analysis showed that the overall complication incidence of radial artery access group was significantly lower (2.5% for radial artery access vs. 4.8% for femoral artery access,